ABBOTT LABORATORIES -- VECTOBAC 12AS, 5605/15576 -- 6840-00N065106
=====================  Product Identification  =====================

Product ID:VECTOBAC 12AS, 5605/15576
MSDS Date:04/29/1989
FSC:6840
NIIN:00N065106
=== Responsible Party ===
Company Name:ABBOTT LABORATORIES
Address:CHEMICAL & AGRICULTURAL PRODUCTS DIV
City:NORTH CHICAGO
State:IL
ZIP:60064
Country:US
Info Phone Num:708-937-6100
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:60060
=== Contractor Identification ===
Company Name:ABBOTT LABORATORIES INC
Address:200 ABBOTT PARK RD
Box:City:NORTH CHICAGO
State:IL
ZIP:60064
Country:US
Phone:847-935-7177
CAGE:60060

=============  Composition/Information on Ingredients  =============

Ingred Name:BACILLUS THURINGIENSIS, SEROTYPE H-14
OSHA PEL:N/K 
ACGIH TLV:N/K 

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD50: (ORAL, RAT) >5,000 MG/KG (SUPDAT)
Routes of Entry: Inhalation:NO	Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INHALATION TOXICITY: ONE OF TEN
    ANIMALS DIES WHEN EXPOSED TO THE MAXIMUM ATTAINABLE CONCENTRATION.
    SKIN: SLIGHTLY IRRITATING WITH SOME SLOUGHING FOUND IN SKIN
    IRRITATION TEST (4-HR APPLICATION) IN RAB BITS. REDNESS, SWELLING
    AND SLOUGHING OF SKIN WERE ALSO NOTED IN DERMAL TOXICITY STUDY IN
    RABBITS WITH (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: A SIMILAR FORMULATION. SENSITIZER.
    EIGHT OF TEN ANIMALS POSITIVE IN A DERMAL SENSITIZATION STUDY IN
    GUINEA PIGS WITH A SIMILAR FORMULATION.
Medical Cond Aggravated by Exposure:DATA SUGGEST PRE-EXISTING SKIN OR
    EYE LESIONS AND HYPERSENSITIVITY TO VECTOBAC FORMULATIONS.

=======================  First Aid Measures  =======================

First Aid:INHAL: REMOVE FROM SOURCE OF EXPOSURE. SKIN: FLUSH WITH
    COPIOUS AMOUNTS OF WATER. IF IRRITATION PERSISTS OR TOXICITY OCCUR,
    SEEK MEDICAL ATTENTION. EYES: FLUSH WITH COPIOUS AMOUNTS OF WATER
    FOR AT LEA ST 15 MINUTES. IF IRRITATION PERSISTS SEEK MEDICAL
    ATTENTION. INGEST: NO KNOWN ANTIDOTE. PROVIDE
    SYMPTOMATIC/SUPPORTIVE CARE AS NECESSARY.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:USE APPROPRIATE MEDIA FOR UNDERLYING CAUSE OF FIRE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT DETERMINED.

==================  Accidental Release Measures  ==================

Spill Release Procedures:RECOVER PRODUCT AND PLACE IN APPROPRIATE
    CONTAINER FOR DISPOSAL. VENTILATE AND WASH AREA.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID EXCESSIVE STORAGE TEMPERATURES
    AND DIRECT SUNLIGHT.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR FOR
    DUST/MISTS.
Ventilation:USE LOCAL VENTILATION TO CONTROL VAPORS.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:NOT DETERMINED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
LD50: FOR A SIMILAR FORMULATION.

==================  Physical/Chemical Properties  ==================

Spec Gravity:1.06-1.1
pH:4.6-5
Solubility in Water:DISPERSES WELL
Appearance and Odor:SUSPENSION. LIGHT BROWN IN COLOR. POTENCY IS
    1200ITU/MG (4.84 BILLION ITU/GAL).

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NOT DETERMINED.
Stability Condition to Avoid:AVOID EXPOSURE TO HEAT.
Hazardous Decomposition Products:NOT DETERMINED.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF PRODUCT IN ACCORDANCE WITH FEDERAL,
    STATE AND LOCAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.